Hardware

A 9U open-frame rack, a firewall built from a refurbished mini PC, a decommissioned enterprise server, and two laptops that were headed for a landfill.

Rack

U Device Role Powered by
U1–U2 APC Smart-UPS X 15001 (mjolnir) Power The wall
U3 HPE ProLiant DL360 Gen92 Proxmox hypervisor (Saruman, BMC shiva) The PDU
U4 1U vented shelf, carrying the 8-port unmanaged TP-Link switch3 Feeds prometheus and oracle A UPS outlet, since 2026-09-08
U5 HP ProDesk 600 G4 Mini4 pfSense firewall (morpheus) The PDU
U6 MT-VIKI 8-port KVM5 Console access The PDU
U7 10-outlet PDU6 Power distribution The UPS
U8 Jadol 24-port patch panel7 Cabling —
U9 MokerLink 26-port managed switch8 Core switching (neo) The PDU

The Powered by column was added on 2026-09-20 and read at the rack that day (#574): everything on the PDU is on the UPS, so a mains cut longer than the pack stops all of it at once, and until that day nothing in this repository said which hosts that was. The UPS's model is read off the card as upsIdentModel and was in no document before then either. Who acts on the pack running out — and who does not — is ADR-0049, and the runtime the pack actually gives at this load is not measured: the card claimed 47 minutes at 21 % load on 2026-09-20, and the one mains pull that turns that estimate into a number is shut-down-on-the-ups.md §6.

Off-rack: two Ubuntu Server laptops on a shelf (prometheus, oracle), fed by the TP-Link in U4; the NAS smaug, a tower in the media room powered from the rack's PDU by a long cord, so on the UPS like everything else on that strip and a subscriber under ADR-0049; and eero Pro 6E units distributed through the house. Both laptops ride a mains cut out on their own cells, so each cell is a dependency of the mains-cut path and is watched as one: Alloy's node collector exports node_power_supply_* from both, and host.rules.yaml alerts when the shelf is off mains, when a cell falls below 80 % of its design capacity, when a laptop reports no cell at all (#454), when a cell reads above 45 °C, and when a host on its cell has under thirty minutes left (#532). prometheus's cell was replaced on 2026-09-18 and reads 101 % of its design capacity at one cycle; oracle's is the original, reads 72 %, and its replacement — a Dell M5Y1K — was bought on 2026-09-19 and is in transit, with eBay's estimate moved to 2026-09-28 (#531). prometheus's runtime was measured on 2026-09-19: 2.72 Ah/h at the stack's load, about 2.5 hours from a full pack, one measurement on one day. oracle's has never been measured. Neither pack reports a moving cell temperature — the Dell exports none, and the A1437 fitted to prometheus returns a constant — so the temperature alert is blind until a pack that measures is fitted, and HostBatteryTempNotMeasured says so.

The patch panel and the PDU were listed the other way round here until 2026-08-29. U8 is the panel and U7 is the PDU, confirmed against the rack. Nothing in this repository depended on the order, but the wiki's rack page had it right and this table did not, so the correction is recorded rather than quietly swapped.

Compute

Host Hardware CPU RAM Storage OS
morpheus HP ProDesk 600 G4 Mini i5-8500T 32 GB 1 TB NVMe SSD FreeBSD 16.0 (pfSense)
Saruman HPE ProLiant DL360 Gen9 2× Xeon E5-2680 v3 (48 threads) 128 GB 2× 1 TB SATA HDD, RAID 1 (pve); 2× 960 GB SATA SSD, RAID 1, LVM-thin large_data Proxmox VE 9
prometheus Apple MacBook Pro (2012, Retina 13") i5/i7 8 GB 256 GB SSD Ubuntu Server 24.04 LTS
oracle Dell Inspiron 15-3565 AMD A6-9200 (2 cores) 4 GB 500 GB HDD Ubuntu Server 24.04 LTS
smaug Lenovo ThinkServer TS150 Xeon E3-1225 v6 (4 cores) 8 GB ECC 240 GB SATA SSD (boot) + 2× 18 TB ZFS mirror erebor TrueNAS 25.10

The observability stack runs on a thirteen-year-old MacBook. It handles four SNMP devices at a 60-second interval, five Alloy agents, and 30 days of metric retention without complaint — which is a useful thing to know before spending money on a monitoring host. Its RAM is soldered at 8 GB and it has no built-in Ethernet, so it reaches the network over a USB NIC.

morpheus has two wired interfaces, and the second is not part of the model: the onboard Intel I219-LM (em0, the WAN) and an Intel I226-V 2.5 GbE card on an M.2 B+M-key adapter9 in the G4's second M.2 slot (igc0, the switch-management LAN and every VLAN). The card is what a restore onto other hardware depends on — restore-the-firewall.md §3 — and it was recorded as a USB NIC in four documents until 2026-09-09, when the box was read directly: pciconf shows it on a PCIe root port, and the only USB device is the Wi-Fi module's Bluetooth half. The table records the release line only, as check_docs.py requires, and unlike the Linux hosts nothing collects the running release from pfSense — so it is written here with its date: pfSense CE 2.9.0-RELEASE, build 20260817-1836, from /etc/version on 2026-09-09. Restoring the config needs a release at least that new (restore-the-firewall.md §3).

oracle was previously recorded here as an i5-1235U with 32 GB and a 2 TB SSD. It is not: it is a dual-core AMD A6-9200 with 4 GB and a 5400 rpm disk. The older entry described a machine that does not exist, which is worth stating plainly because it was load-bearing in planning.

The OS column names the release line and not the point release. Both laptops were recorded here as 24.04.3 while both were running 24.04.4, and check_docs.py could not see it — it compares this table against network.md, and the two copies were stale together. A point release changes when a host takes an update, which is not an edit to this repository, so it is the wrong kind of fact to write down at all: the running version is already collected on every Linux host as node_os_info{pretty_name="Ubuntu 24.04.4 LTS"}. The check now rejects a third version component in either table.

Management

Host BMC Address Notes
Saruman shiva — HPE iLO 4, firmware 2.82 10.0.30.10 iLO Advanced licensed. Dedicated network port. DHCP with a reservation. Hardened 2026-09-09 per ADR-0033: IPMI-over-LAN, SSH and iLO Federation off; HTTPS, the remote console and SNMP stay on; the account's credential is shared with nothing else; the security log was read for a baseline. Polled over SNMPv3 authPriv (SHA, AES, user prometheus) since 2026-09-20 per ADR-0036, with SNMPv1 Request off — it answers no community at all

The BMC and the host it manages carry different names and different addresses: shiva is the iLO, Saruman is the hypervisor at 10.0.30.110. Earlier revisions of this repository treated shiva as the hypervisor itself.

Accessories

  • 1U rackmount tray for the ProDesk Mini10
  • Sliding rails for the ProLiant11
  • 1U universal rack mount for the APC12
  • APCRBC115 replacement battery cartridge for the APC, fitted 2026-08-28, proven by a passing self-test the same day and under a biweekly schedule on the card (#93). The card's upsBasicBatteryLastReplaceDate still reads 08/15/2026 and wants resetting to the fit date — it is the only record of the pack's age
  • 1U vented rack shelf, 4-post with square-hole mounting — in U4 since 2026-09-08, carrying the unmanaged switch that feeds prometheus and oracle (#110)
  • HP ProDesk 600 G4 Micro13 — i5-8500T, 32 GB, 512 GB SSD, the same model as morpheus — ordered 2026-09-08, in hand since 2026-09-14 and opened on 2026-09-15. This is trinity, and it is one box with two jobs, not two boxes: the sensitive tier's host, and the firewall's spare hardware in a disaster (ADR-0034). The documents call it "the tier's host" in one place and "the spare" in another, which is how it came to be read as two machines (ADR-0038); a second ProDesk is deferred, not ordered. This entry read "in hand since 2026-09-15" until 2026-09-17. The carrier's notice puts the drop-off at 15:05 local on the 14th; the commit that recorded it was written that evening and dated by UTC, which had already turned over. The opening date is a separate reading and stands. It enters the Compute table when #404 builds it, after the firewall restore has been rehearsed on it. It ships with the onboard NIC only; the I226 card the restore depends on was a separate purchase, made 2026-09-11 and the entry below — in hand and fitted since 2026-09-25. So what the rehearsal waits on is no longer this box or the card: it is the installer stick alone. The 512 GB SSD is M.2, and the second M.2 slot is free — read off the machine on 2026-09-15, and the answer the entry below was waiting for. There is no drive carrier and nothing contended: the I226 card went into that slot on 2026-09-25, and the contingency the documents carried since 2026-09-11 did not fire. It arrived carrying Windows 11 Pro, sold refurbished with a licence. The rehearsal's first act is to wipe it, so that licence is spent rather than banked: it is OEM, it dies with the install it shipped on, and it did not stand in for the two Windows 11 Pro keys in the buy table (roadmap.md). Those were bought separately on 2026-09-25 and are activated on carbuncle and siren, the lab domain's two endpoints (ADR-0029, #414) — a different machine and a different decision. The warranty runs to 2027-09-08 — one year from purchase, through SquareTrade, applied automatically because it was sold as eBay Refurbished. It is worth recording because ADR-0034 accepts that the tier is down until a replacement arrives: inside that year a dead trinity has a claim behind it, and after it the ADR's cost is the whole cost. The seller-return window closes 2026-10-08, thirty days from purchase. That is a deadline on the list below rather than a fact about the machine. Still the listing's claims rather than the machine's, and still to be read: the i5-8500T, the 32 GB and the 512 GB above, the serial and the product number off the case, and that it really does have the onboard NIC alone — read them before that date. Installing pfSense over the Windows partition is what ends the return and is the one step of the rehearsal that cannot be taken back, so the machine has to be proved while sending it back is still an option. It waits on nothing.
  • Intel I226-V 2.5 GbE card on an M.2 B+M-key adapter — bought 2026-09-11, in hand since 2026-09-25 and fitted in trinity the same day. The second port on the ProDesk Micro above, matching the card in morpheus so a pfSense restore onto the spare brings the LAN up as igc0 and asks nothing (restore-the-firewall.md, #404). It is the one entry on that runbook's prerequisite list that was still unbought, and it is deliberately not a USB NIC: a USB adapter comes up as ure0, which is the one thing a restore must not be asked about. It goes in the G4 Micro's second M.2 slot, and that slot is free: the box was opened on 2026-09-15 and its 512 GB SSD is M.2, so there is no 2.5" drive carrier to contend with. This entry carried the opposite contingency from 2026-09-11 until then — that a carrier and this card would want the same space, and that one of them would have to go. It was a real risk and it did not happen; recorded as answered rather than deleted, because the reason the card was bought before the box was opened is the part worth remembering. The free slot took it, fitted on 2026-09-25 — morpheus is the same model and does exactly this, which is why the same model was bought. Still to read: the part number off the card, and the port's MAC. The Windows the box shipped with shows the MAC before the rehearsal wipes it; after the install, FreeBSD shows it on igc0, which is also the proof that the driver claimed the card.
  • 2 TB USB portable hard drive — on hand, previously a games console's storage. Becomes the photo library's disk on trinity (#404): Immich's originals on it, its database on the internal SSD, after a wipe and an ext4 format. One consumer spinning disk with no mirror, so the off-estate copy ADR-0023 requires is what protects it — the same as would have been true of a bought drive, which this replaces.
  • Lenovo ThinkServer TS150 — Xeon E3-1225 v6 (4 cores, 3.3 GHz, Intel HD P630 with Quick Sync), 8 GB ECC, four 3.5" bays, no drives, no OS — bought 2026-09-09, in hand since 2026-09-15. The NAS smaug of ADR-0016, tracked under #413. A tower, not a rack unit, and a 73 W part where the ADRs pictured an N100. It entered the Compute table on 2026-09-16, which is the trigger this entry set for itself — placed, addressed at 10.0.40.30, and in network.md. It is powered from the rack's PDU by a long cord to the media room, read at the rack on 2026-09-20 — the one sentence #413 owed this entry, and the fact #574 could not find: the box is on the UPS, so a cut longer than the pack is a deferred unclean stop for the mirror rather than an immediate one, and ADR-0049 makes it a subscriber that halts on the signal instead. The Storage column reads the boot disk alone on purpose: the ZFS mirror does not exist until the two Exos drives land, and a Storage column describing a pool nobody has created would be the kind of claim this table exists to not make. The boot disk the TrueNAS install wants (ADR-0040) and the bracket that carries it in the optical bay are the entries below and landed with it; the two drives for the mirror, bought 2026-09-11, landed on 2026-09-18 and were in the bays that evening. The Storage column reads the mirror since 2026-09-19. Nothing for this machine was outstanding on the roadmap's list from 2026-09-18 until 2026-09-21, when memory re-entered it (#599) — the pool and the transcoder both landed after the box was specced, and neither was weighed against the one DIMM below when it was. Read off the machine on 2026-09-15, where everything above it came off a listing: ThinkServer TS150, machine type-model 70UB000AUX, serial MJ05N4NK. Xeon E3-1225 v6 at 3.30 GHz, four cores, and Active Video: IGD — so the P630 this box was chosen for is live, which is the hardware half of ADR-0040's reopen condition and not the whole of it; whether Quick Sync reaches a container was tested on 2026-09-19 and it does — a hardware decode, scale and h264_qsv encode inside the Jellyfin container, per build-the-nas.md §6.1. 8192 MB at 2133 MHz, which is one Samsung M391A1G43EB1-CPBQ — 8 GB 2Rx8 PC4-2133P, ECC unbuffered, date code 1728 — in one of four slots. More memory is therefore an add and not a replace, and the part to match is ECC unbuffered: a registered DIMM will not run on this board. The label was photographed on 2026-09-21 and reads PC4-2133P-EE1-11, which is the same constraint in the form a listing photograph can be checked against: in the JEDEC module marking the two letters after the speed grade are the module type, and EE is ECC unbuffered. RA or RB is registered and will not POST here, LD is load-reduced and will not either, and UA or UB is unbuffered without ECC — which this board does accept, and which ADR-0040 rules out anyway, ECC being ZFS's home ground. Read those two letters rather than the vendor part number: most DDR4 sold as server memory is RA. The same label confirms every field this entry already carried, which is why it is recorded as a check rather than a correction. The board takes four DDR4 UDIMMs at 2133 or 2400 to a maximum of 64 GB, so 8 GB is an eighth of what it holds and three slots are empty. #599 takes it to 32 GB, and it does so by filling the board rather than by halves: three more of the same 8 GB part, bought 2026-09-22, in the entry below. The roadmap row that left the buy list that day had said 32 GB with two slots still free, which would have meant two 16 GB modules; new ECC unbuffered 16 GB ran $134 to $140 each against $44 for this part, and the 2133 stick already fitted sets the clock for whatever joins it either way. The cost of that choice is named rather than discovered later: at four slots occupied, 64 GB is a replacement of all four modules and not an addition, so the board's ceiling is reachable only by discarding what is in it. 32 GB is the number ADR-0040's workload was sized against, and the second half of the ceiling was never costed. Onboard NIC 4c:cc:6a:xx:xx:xx, recorded as an OUI like every other address here. BIOS S06KT81L dated 2024-02-05, boot block 1.81, flashed 2026-09-16 while the box was still empty. It shipped on S06KT03R dated 2017-05-22 with boot block 1.03 — a firmware predating the Spectre and Meltdown microcode by a year — and the flash was done before the pool existed precisely so that a reset of Configure SATA as or of CSM would cost a re-check rather than an unbootable host with data on it. Both were re-checked and both survived, as did the machine type-model, the serial, the UUID, the MAC and the clock. The embedded controller did not move: it read S06CT01A before and reads S06CT01A after, and whether the package updates that component at all is unestablished — recorded as an observation rather than as a failure, because nothing misbehaves and the BIOS half plainly took. Intel AMT was enabled and on its factory-default credential when this box arrived, and is now off. Intel ME v11.6.12.1204, MEBx v11.0.0.0012: the MEBx accepted admin on 2026-09-16, which is Intel's default and means nobody had ever set one — the same class of thing the CRS326 entry below warns about, that a used device arrives carrying whatever its last owner left on it. Manageability Feature Selection read Enabled, Password Policy the stock Anytime, and the ME network name and domain were both blank, which is the evidence it had never been provisioned onto a network rather than a proof of it. Closed the same day, in the order the firmware requires: a new ME password (MEBx forces one at first login, and it lives in the operator's password manager), then Unconfigure Network Access → Full Unprovision while the feature was still enabled, then Manageability Feature Selection → Disabled. Verified by the <CTRL-P> prompt no longer being offered at boot. Disabled rather than hardened, which is the opposite of what ADR-0033 decided for shiva, and the difference is the host's job rather than a change of posture: Saruman is headless in a rack and a remote console is load-bearing there, so its iLO was kept and locked down. smaug is a tower with a monitor beside it, on the segment with the televisions and the consoles. Out-of-band management buys it nothing and would cost a management plane that answers when the operating system is off. Six SATA ports, all enabled, and two settings that were already right rather than needing changing: Configure SATA as [AHCI], which is the raw-disk access ZFS wants and the thing #418 is the cautionary tale for, and CSM [Disabled], so it boots UEFI as TrueNAS wants. Two 3.5" trays, filled by the Exos pair on 2026-09-18 — exactly the mirror and no spare. The trays are not on those six ports. Read with lspci and readlink at the console on 2026-09-19, while triaging the faulted disk: both Exos enumerate under host0 at PCI 01:00.0, a Broadcom / LSI MegaRAID SAS-3 3008 "Fury", PCI ID 1000:005f — the SAS3008 in its MegaRAID personality, which is the ThinkServer RAID 520i option for this chassis, sitting in the PCIe slot and cabled to the bays. The chipset AHCI at 00:17.0 carries only the boot SSD on ata6; ata1–ata5 read SATA link down at boot. So Configure SATA as [AHCI] protects the boot disk and nothing else, and the pool has had a RAID controller between ZFS and its disks since the day it was built — the arrangement the line above calls #418's cautionary tale. It is the MegaRAID firmware, not the chipset, that handled sdb's failure with 60-second command timeouts, task aborts and a target reset. smartctl reaches the drives without a -d megaraid option and reports them by their own model and serial, which is what a JBOD pass-through looks like — and dmesg confirms it, read the same night: driver megaraid_sas 07.727.03.00-rc1, controller type iMR(0MB) — the cacheless entry-level MegaRAID, no write cache and no battery to worry about — subsystem 1000:9340, which is the 9340-8i family the ThinkServer RAID 520i is built on, Secure JBOD support: Yes, and JBOD sequence map : enabled, which is the driver's way of saying the disks are JBOD devices rather than virtual drives. So ZFS sees the drives themselves through a RAID firmware's error handling, which is the better of the two arrangements a MegaRAID offers and still not an IT-mode HBA. The firmware version is not in dmesg and not in sysfs either — /sys/class/scsi_host/host0/fw_ver does not exist, read 2026-09-19, and megaraid_sas exposes crash-dump and queue attributes there and nothing about its firmware. TrueNAS ships no storcli. So the version is read off the card's own boot-time utility. Read 2026-09-22 at the power-on after the faulted disk came out, in the UEFI setup's Advanced → AVAGO MegaRAID Configuration → Controller Management: product AVAGO MegaRAID SAS 9340-8i, PCI ID 1000:005F:1000:9340, package 24.16.0-0104, firmware 4.660.01-8219, NVDATA 3.1605.01-0008, two connectors, status Optimal, no BBU, zero virtual drives, and the one remaining Exos on drive port 0 as JBOD. That reading is what #571 was owed. The card is coming out, by decision, 2026-09-23 (ADR-0052): at the swap, the Exos pair moves to the chipset's free ports on two plain SATA cables, bought for it because the only tray cable is the card's own mini-SAS breakout. The card and the breakout go on the shelf as the fallback. Until the swap, everything in this paragraph describes the path as it still is. The driver logged a disable/enable of its interrupts at 21:03:51 on 2026-09-19, the same second as the target reset in the fault's dmesg — the controller resetting itself around a disk that had stopped answering, which is the Online Controller Reset it advertises as enabled. 1000:005f is the ID to watch: 1000:0097 is the same silicon in IT mode, and the card was never recorded here, like the optical drive was not. Cabling below, in build-the-nas.md §1, says SATA2 and SATA3; that is now known to be wrong, and the same reading corrects it. The 5.25" bay was not empty: a PLDS DVD-RW DU8AESH answered on SATA5. A photograph of the open case had been read here as an empty cage and was wrong; the BIOS summary is what caught it. The optical drive came out on 2026-09-16 and the boot disk took its place, its port and both its cables. The bay is a cage carrying its own fan on the board's AUX1_FAN header, and that fan is not optional: it is the airflow over the drive bays, and two 7200 rpm Exos under a scrub will want it. Reconnected after the swap and reading Aux Fan: Operating.
  • 2× Seagate Exos X20 18 TB (ST18000NM003D, firmware SN03), 3.5" SATA14 — bought 2026-09-11, in hand since 2026-09-18, a day after the carrier's window lapsed. smaug's ZFS mirror (ADR-0016, #413). A mirror of two is one drive's capacity, so this is 18 TB usable, not 36. Read off both drives with smartctl -a at the console on 2026-09-18, before the pool existed: serials ZVTBS4NL and ZVTBSDL3, both PASSED, both at 0 power-on hours, 0 reallocated, 0 pending, 0 uncorrectable, no errors logged, 26 °C in the bays against a lifetime range of 24–26. The zero hours is a fact, not a claim, and it was checked the one way that settles it. SMART's hours counter can be reset, and used Exos drives with it zeroed were sold as new through 2025; Seagate's FARM log keeps a second counter that the reset does not touch, and smartctl -l farm on this host read 0 power-on hours and 0 spindle hours on both drives. What the resettable counters add is consistent with new drives bench-checked by the seller and with nothing more: ZVTBSDL3 arrived carrying a Windows quick format — a 16 MB Microsoft reserved partition and an NTFS volume labelled New Volume filling the rest — with 718,258 LBAs written, about 370 MB and the size of that format, three power cycles, and one short self-test logged at lifetime hour 0; ZVTBS4NL arrived blank, two power cycles, nothing written. Both spun up and enumerated on the first power-up. The TS150's SATA power lead has four wires and no orange one, read on 2026-09-18, so this supply puts nothing on pin 3 and the Power Disable trap build-the-nas.md §1 records does not apply on this box — it would on a supply that does. They entered the Compute table with the pool. Both extended self-tests completed without error. Started 2026-09-18 at lifetime hour 0, under the pool creation and the first day of the stack, and read on 2026-09-20 with smartctl -l selftest: ZVTBS4NL (sda) logged the completion at lifetime hour 25 and ZVTBSDL3 (sdb) at 26, no LBA of first error on either, and sdb's log still carries the seller's short test at hour 0 above it. That was the last open line of build-the-nas.md §7, and #413 closed on it. ZVTBSDL3 (sdb) FAULTED on 2026-09-19 at 20:55 PDT (03:55 UTC 2026-09-20), at about lifetime hour 27 — one day after arrival and about an hour after the extended self-test above completed clean. TrueNAS raised "Pool erebor state is ONLINE: One or more devices are faulted in response to persistent errors … Disk ST18000NM003D-3DL103 ZVTBSDL3 is FAULTED". node_exporter's /metrics had stopped answering at 20:46, nine minutes earlier, with the port still accepting connections, so InstanceDown was the page and ZpoolNotOnline — the rule this fault produced — never got a sample. ZVTBS4NL carries the pool alone until a replacement is fitted; the return runs under the eBay guarantee, thirty days from the 2026-09-18 delivery, to 2026-10-18. What dmesg and SMART said at the console, and the outcome, belong in replace-the-nas-disk.md's status block and then here; #558 carries it. Read at the console on 2026-09-19 at 23:19 PDT, at lifetime hour 32: it is the drive. zpool status counts 3 read and 99 write errors on the leaf; dmesg is Logical unit not ready and 60-second command timeouts from 20:47 on, with no link resets and no CRC errors; SMART reads 850 pending and 850 offline-uncorrectable sectors against the 0 and 0 of the day before, Command_Timeout normalised to 1, overall health still PASSED; and FARM puts all 850 reallocation candidates on head 5, with 124 command timeouts and 179 hardware resets, both rails in spec, 28 °C. ZVTBS4NL is unaffected. The extended self-test that completed at hour 26 was true when it was read and is not evidence now. The return was opened on 2026-09-20 under the eBay guarantee, as defective; the label is due by 2026-09-24, and the seller had not chosen refund or replacement when this was written — a replacement means no purchase, a refund means an 18 TB bought outright and a row in roadmap.md's buy list. Seagate's warranty, read 2026-09-22 with the tray out: none. The label's QR code verifies as a genuine 18000 GB drive, so the "0HR" lot is not relabelled stock, and Seagate's lookup for ZVTBSDL3 says "Your product is not under warranty. Please contact the place of purchase." The eBay return is the only remedy. ZVTBS4NL came from the same lot and was not looked up, because its tray stays in; assume it is the same until it is read. Wiped and pulled 2026-09-22, runbook step 4. Offlined in the UI; shred -n 1 ran on /dev/sdb, confirmed ZVTBSDL3 by smartctl -i, at about 215 MB/s, which is a day or more for 18 TB. It was stopped at 93 GiB for time, so the fallback ran: zpool labelclear -f refused (failed to clear label, because shred had already overwritten the front), then a dd of zeros over the first and the last 1 GiB, both complete. wipefs then listed no signature and sdb1 no longer existed. The labels and partition tables at both ends are gone; the data blocks between 93 GiB and the last GiB were not overwritten. The drive took every write it was given, so this was a choice made for time and not a refusal. Tray pulled by its label, and shipped on eBay's label on 2026-09-22. erebor reads DEGRADED on ZVTBS4NL alone, 0 0 0, No known data errors. One correction from the same day: TrueNAS's alert did not stop at the web UI. TrueNAS Connect emailed it to the operator's mailbox 37 s after it fired, which is a mailbox rather than a page, and a cloud service this host initiates a connection to — #483's subject. The return came back as a refund, not a replacement. The drive reached the carrier on 2026-09-23, and eBay issues the refund within three days of the seller receiving it. So the replacement is a purchase, and it is the entry below. ZVTBSDL3 stays in this entry as the drive that faulted.
  • Seagate Exos X20 18 TB, ST18000NM003D15 — 3.5" SATA 6 Gb/s, 7200 rpm, eBay Refurbished, from goharddrive. Bought 2026-09-24, in transit, with an estimated delivery of 2026-09-26 to 2026-09-29, under #558. $499.99 and $51.50 tax, $551.49 all in. It replaces ZVTBSDL3 in erebor's mirror, alongside ZVTBS4NL. It is the same part number as the pair above but not the same lot or seller. That pair was sold as new "0HR" drives, and Seagate's lookup found no warranty on them. This one is sold refurbished, with eBay's refurbished-programme warranty serviced by Allstate rather than Seagate's own. It was bought the day the refund answer came in, because erebor is one disk until it is fitted and the roadmap's NAS milestone waits on that. It went straight to a purchase rather than through the buy table (roadmap.md). Checked on arrival, not assumed: the serial and its warranty status by Seagate's lookup, SMART's power-on hours, reallocated and pending counts before it goes in a tray, and a long self-test. Then replace-the-nas-disk.md's fit, resilver and scrub. A refurbished drive's hours are the listing's claim until SMART reads them. The Compute table still reads a two-disk mirror, and the pool is whole again only when the resilver completes.
  • Intel DC S3520 240 GB, 2.5" SATA 6 Gb/s enterprise SSD with power-loss protection — bought 2026-09-11, in hand since 2026-09-15. smaug's boot disk, carrying TrueNAS and the media stack it launches (ADR-0040, superseding ADR-0016's Ubuntu Server), deliberately not the mirror — an arrangement TrueNAS wants anyway, since it keeps its boot device out of the pool entirely. A data-centre part where the roadmap asked only for "a 240–256 GB 2.5" SATA SSD": the endurance is beside the point for a boot disk, but the power-loss protection is the same property the SM863a pair was bought for, and a boot disk that survives a power cut is worth more here than one that is merely fast. The TS150's optical bay is 5.25" and this is a 2.5" drive, so it cannot be fitted bare: a bracket for the bay and double-sided tape to mount it were bought 2026-09-11, alongside the drive, and both landed with it on 2026-09-15. The bracket is a 5.25"-to-2.5" adapter and does fit both the drive and the bay — an assumption until it was fitted. It and the tape are still unnamed here, which is a naming this document owes rather than one it is waiting on. Fitted 2026-09-16 and detected: the BIOS summary reads SATA Drive 5 Hard Disk INTEL SSDSC2BB240G7, and the G7 suffix is the S3520 generation — so the part is what the listing said, on the port the optical drive vacated, with both its cables inherited rather than found. Serial PHDV706401TM240AGN, firmware N2010101, on SATA 3.1 at 6.0 Gb/s. smartctl read 2026-09-16, and it is a used drive with a history worth recording: SMART self-assessment PASSED, Media_Wearout_Indicator 088 — Intel's own counter, which starts at 100 and falls, so roughly a tenth of the write endurance is spent and the rest is ample for a disk that will carry an operating system and no data. 13,182 power-on hours, about eighteen months running. Around 72 TiB written by its previous host. Zero pending sectors, zero reported-uncorrectable, zero CRC errors, zero end-to-end errors, and 24 °C in the bay with the fan on. 509 unsafe shutdowns out of 538 power cycles, which is the number that says what this drive did before: it was almost never shut down cleanly. Re-read at the console on 2026-09-21: 519, at 13,301 power-on hours — ten more in the five days since the install, on a host that has been up throughout, which is the counter #574 wants watched and the reason ADR-0047's collector now reads it. Note that this drive reports it under two attributes, 174 and 192, both of which smartctl names Unsafe_Shutdown_Count; the collector renders one series and says why. It is also the argument above, tested. This part was chosen because a boot disk that survives a power cut is worth more here than one that is merely fast, and Power_Loss_Cap_Test still passes after 509 of them — the capacitor works and somebody else did the proving. Four reallocated sectors, and that is a number to watch rather than to reject — normalised 099 against a threshold of 000, with nothing pending and nothing uncorrectable behind it. It has a consequence that is better written down now than discovered later: SmartDriveBadSectors holds every drive to the reallocated count already recorded for it, and to zero when none is, because a remapped sector never un-remaps and the first one is the finding. So this drive's four are recorded, in scripts/render-smart-baselines.sh beside oracle's 32 with the day they were read — the answer #572 built in place of the silence #351 used, because a silence matches labels and no label carries the count, and a baseline lives in git and does not expire. SmartDriveBadSectorsGrowing carries the trend above it. The row is inert until build-the-nas.md §6.4 runs the collector on this host — a root cron job under the scrape, by ADR-0047, which closed #483 — and its device letter is confirmed that day from what the collector prints. Since that ADR the collector also reads this drive's wearout indicator, so SmartDriveWearHigh can see it, and its unsafe-shutdown counter, which is the number #574 asked for and SmartDriveUnsafeShutdownsGrowing now reads (ADR-0049). SmartDriveWearHigh will not fire — it wants 80 % of rated life used and this is near a tenth. No self-tests had ever been logged in 13,182 hours, so a baseline was taken on 2026-09-16 before the machine carried anything: extended offline, completed without error, at lifetime hour 13,183. The drive took far longer than its own two-minute estimate because it advertises Suspend Offline collection upon new command and TrueNAS was live underneath it — worth knowing before reading a slow self-test as a sick disk. TrueNAS's scheduled tests take it from here; they run the tests, and ADR-0047 publishes the attributes.
  • 2× Samsung SM863a 960 GB (MZ-7KM960N), 2.5" SATA 6 Gb/s enterprise SSDs with power-loss protection16 — purchased 2026-09-09, delivered 2026-09-11, fitted 2026-09-18 in bays 3 and 4 of the ProLiant, and since 2026-09-19 the P440ar's logical drive 2: RAID 1, 915683 MB, carrying the LVM-thin pool large_data (volume group, pool and Proxmox storage id are all that one word). Bought against the number every sizing decision on Saruman starts from: a 7.2K mirror serving about ninety random write IOPS (ADR-0029). Measured 2026-09-20 (fit runbook step 8: 4 KiB random write, queue depth 1, direct=1, an 8 GiB thin volume on each pool): the HDD mirror does 741 IOPS idle and 734 with the guest live, 1.3 ms mean and 12.5 ms p99, against the derived 83 — the controller's battery-backed write cache, which ssacli reads as 10% Read / 90% Write and the iLO reads as 0, is absorbing writes; at queue depth 32 the mirror sustains 712. The SSD mirror does 7,952 IOPS at queue depth 1, 102 µs mean and 198 µs p99, and 51,600 at queue depth 32 — on SSD Smart Path, with no controller cache in the path. Serial S3F3NX0K601487 in Bay 3 and S3F3NX0K806107 in Bay 4, firmware GXM5304Q, both negotiated at 6 Gb/s — as the iLO reports them over SNMP, not as read off the labels. The fit runbook asked for the labels first, because reading a serial back through the controller means reading it through the tool the fit is trying to verify; that was not done while the drives were unassigned, and the window closed when they joined an array. The iLO gives the model only as SAMSUNG — it names a third-party SATA drive by vendor where it gives the HPE disks their part number — so the part is proved by the size (915715 MB), the firmware and the serial prefix rather than by the model string. Both read solid-state, SMART ok and notConfigured from the first scrape they appeared in, at 20:11 UTC on 2026-09-18, and configured from 13:40 UTC the next day, the scrape the logical drive first appeared in — created through the offline Smart Storage Administrator, not ssacli, which reached the host that evening from HPE's trixie suite and read the controller for the first time. The array read ok from its first scrape and nothing alerted for it; what did alert was the fourteen-and-a-half-hour power-off the SSA session sat inside, which the runbook now records. The iLO's wear columns stayed blank once the drives were configured — wear status other, endurance and power-on hours unknown — which is the condition #529 was filed against, so wear on these two drives is #529's to read through hpsa, and ssacli agrees: both report SSD Smart Trip Wearout: Not Supported. alexander has lived on large_data since 02:41 UTC on 2026-09-20 — a 100 GiB disk mirrored across online in 7 min 28 s, unused0 removed, ssd=1 set, and rebooted so the guest sees a non-rotational disk. The cache reading #76 waited on since 2026-09-02 is taken and is the iLO's blind spot, not the controller's: the ratio is set and the cache is working. The numbers above are what #527 closed on, and the ADRs whose arithmetic they replace carry dated notes rather than edits. The two spinners in bays 1 and 2 are SATA, not the SAS this table said until 2026-09-20 — Interface Type: SATA, MM1000GBKAL, read by ssacli — which changes no decision and one word. This entry is where the serials live, which is the question #148 asked.
  • 2× HP 2.5" SFF drive tray, 651687-00117 — bought 2026-09-11, arrived and fitted 2026-09-18, one under each SM863a in bays 3 and 4. The carriers the pair above needs to sit in Saruman's SFF bays (#418). A Gen9 bay holds a drive only in a tray, so two drives want two trays, and two is what was bought — worth writing down, because one tray short is one SSD fitted and one on a shelf. The arrival checks this entry asked for are answered by the bays rather than by the packaging: both trays took a drive, and the iLO reads the same carrier firmware on all four bays (cpqDaPhyDrvSmartCarrierAppFWRev 11, bootloader 6), so they are the Gen8/Gen9 SmartDrive carrier and not the Gen10 part or the 3.5" LFF one. This purchase went unrecorded for six days, which is the omission this entry exists to close. It was made in the same sitting as the I226 card, the Exos pair, and the boot disk's bracket and tape, every one of which has had an entry here since the day it was bought. The roadmap's rule is that a purchase is written down when the money is spent, so a gap like this is the rule failing rather than a thing the rule allows. Found on 2026-09-17 while reading the ProDesk's arrival paperwork for #92, which is not a way of finding purchases that can be relied on. 651687-001 is the listing's part number, not read off the tray.
  • MikroTik CRS326-24G-2S+RM18 — 24 × 1 GbE, 2 × SFP+, 1U, dual-boot RouterOS / SwOS — bought used 2026-09-13, in hand since 2026-09-23. The box held the switch and its rack ears and no power adapter. The rear panel has no AC inlet: the only power input is a barrel jack marked DC 10–28V, beside a ground screw, with a blank plate where other units carry an inlet. PoE-in on port 1 is the other input. MikroTik rates the unit at 24 W maximum. A MikroTik 24HPOW19 (24 V, 2.5 A, North American cord) was ordered 2026-09-23 and is in transit, and the bench steps wait for it (#444). Not 48POW: it is MikroTik's too, has the same plug, and puts 48 V into a jack labelled 10–28 V. The replacement for neo that ADR-0018 asked for in its last consequence and #444 decided. It is bought for one property, a TLS management interface: RouterOS serves its UI over www-ssl and imports a certificate, so the switch admin credential stops crossing the wire in clear through the device it protects. #84's GETBULK residual rides along; SNMPv3 is not the argument, because ADR-0036 found the switch in the rack already answers v3 on the wire. How it is configured was decided before the window rather than during it — ADR-0041 runs it on RouterOS, keeps the name neo and the address 10.7.7.2, serves www-ssl from a leaf off the estate's CA with plain www off, and gives it an SNMPv3 authPriv user; the procedure is swap-the-switch.md. It enters the Rack table at U9 and network.md when it is racked — neo carries every VLAN, so the swap is a house-wide outage and shares a rack visit rather than getting its own — and until then neo is the switch in every document and every target. Checked on arrival, not assumed: which OS it boots and the version on it (/system resource), the serial and the management MAC, that the rack ears and the power supply are in the box, and a netinstall or factory reset before it touches the network — a used RouterOS device arrives with whatever its last owner left on it, users included. Those go here when it lands.
  • USB stick holding the pfSense installer — in hand since 2026-09-26; it belongs in the rack beside the KVM once #92's rehearsal has used it. restore-the-firewall.md lists it as something you will need, so a restore attempted before it lands is a restore that stops to go looking for one
  • HP Smart Storage Battery 96W (727258-B21, spare part 815983-001) in the ProLiant, fitted 2026-09-02 to replace the pack that had failed. The Smart Array re-enabled its write cache on the first scrape after the fit; the cache ratio it reports is still open (#76)
  • A1437 battery cell for prometheus20 — the pack that fits the A1425, the late-2012 Retina 13" in the Compute table — bought new 2026-09-13, delivered 2026-09-18 and fitted the same day. A consumable and not an upgrade: it is the one exception the roadmap's Never line names, bought because the estate's mains-cut path rests on this cell and the failure mode of a thirteen-year-old lithium cell on a shelf is swelling (#454). The listing calls it genuine and its brand field says unbranded, so it is recorded as a compatible cell, not an Apple part. That wording was written to be settled once the part could be looked at, and the fit settled it sideways. manufacturer and model_name came back unchanged — SMP, bq20z451 — because an aftermarket A1437 reuses the same gas gauge; but both design figures moved, charge_full_design 6.6 → 6.8 Ah and voltage_min_design 11.21 → 11.4 V, which is a pack reporting its own numbers and is the only proof of a different part available on a machine that exports no serial. It stays recorded as a compatible cell. The new pack reads charge_full 6.889 Ah of 6.8 Ah design (101 %) at cyclecount 1. The cell it replaced read 94 % of design capacity after 108 cycles, on 2026-09-12 and again on 2026-09-17 — above HostBatteryHealthLow's 80 %, so it was bought on age and not on the alert — and went for recycling on 2026-09-18. Nothing in the Compute table changes; a cell is not a spec. Checked at the fit: charge_full above charge_full_design, cyclecount 1, charge_ampere moving, and both design figures changed — all read from this host's own Prometheus on 2026-09-18. Checked on 2026-09-19, and the check that closed #454: the mains pull on the fully charged pack. The host stayed up for a bounded 22 minutes on the cell, HostOnBattery fired for it alone, and the draw measured 2.72 Ah/h — about 2.5 hours from full at the load the stack presents, the first runtime figure the estate has had for either laptop, and one measurement on one day. (replace-the-laptop-cell.md carries the baseline, the stack-down window — 14:53 to about 18:12 on the day, over its own two-hour bound — and the disposal.) oracle's cell reads 72 % and is second in line, bought 2026-09-19 — the entry below.
  • Dell M5Y1K 4-cell pack for oracle21 — 14.8 V, 40 Wh, the latched pack the Inspiron 15-3565 in the Compute table takes. Identified and bought 2026-09-19, in transit, under #531: the part was written down here before the money was spent, which is the order that issue asks for, and the purchase followed the same day. The listing calls it genuine Dell, which — as with the A1437 above — is the listing's claim until the pack is looked at; a Dell label and a serial_number that is not 1650 are what would settle it, and the fit records which it turned out to be. The listing quoted delivery in two to four days. It had not arrived by 2026-09-26, and eBay's estimate had moved to 2026-09-28. The number comes off the machine rather than off the listing: /sys/class/power_supply/BAT0 reports model_name DELL VN3N047, and VN3N0 is one of the interchangeable Dell part numbers for this pack — M5Y1K is the primary, and WKRJ2, HD4J0, 991XP and GXVJ3 the others listings carry — with manufacturer SMP-Sanyo2 and serial_number 1650. The design figures agree with the part: 2.8 Ah at 14.8 V is the 40 Wh on the label. It is the second laptop cell and the same consumable exception as the A1437 above, second in line because prometheus dying is the estate going blind and oracle dying is the wiki and the off-host jobs going quiet (#454). It measures worse than the cell that exception was written for: charge_full 2.021 Ah of 2.8 Ah design, 72 %, read 2026-09-12 and unchanged on 2026-09-19 — the same figure across the whole 30-day retention — below HostBatteryHealthLow's 80 % line, and that alert has fired for it since 2026-09-14 under a silence that expires 2026-10-08. A bare battery, not a kit: unlike the MacBook's glued cell this one sits behind a slide latch on the underside, so the swap is a latch and a lift with the machine off, and needs no solvent, no screws and no tools. The machine's coin cell is a separate CR2032 behind the keyboard and palmrest, which a latch swap never reaches — the reason its clock is expected to survive the disconnect that reset prometheus's (#519), and a thing the fit checks rather than assumes. What proves the swap differs from the MacBook too: this pack's info series carries a serial_number, which the MacBook's does not, so a changed serial is the clean proof row; and its firmware reports cyclecount as 0 always and exports no temp_celsius, so two of the MacBook's rows are unavailable here. replace-the-laptop-cell.md has the procedure and a section on what differs on this host. Nothing in the Compute table changes; a cell is not a spec.
  • Three Samsung M391A1G43EB1-CPB22 — 8 GB DDR4-2133 ECC UDIMM, PC4-17000P-E, dual rank x8 — bought 2026-09-22 under #599, shipped FedEx 2026-09-25 and in transit. The seller held the order for an identity check. The check was answered and the order released the same day. smaug's memory, and the same part as the module the machine already carries: this is the matched-set answer to that issue rather than the two-16 GB one, for the reason the Compute entry above now records. $44 each, $132 the three, $15.30 FedEx 2Day, $147.30 all in, from Memory.NET with a lifetime warranty on the modules. New, not pulled — the used market for this part sat between $19 and $45 a stick with no warranty, so the premium here is small and buys the replacement path. It takes the board to 32 GB across all four slots, and what the arrival has to check is what no listing can answer: that three strangers and the incumbent train together at 2133 and that the board posts with every slot filled. Until then the Compute table reads 8 GB, because memory in a box in transit is not memory in the machine. Ordered the day after the label was photographed, which is what settled the part number — PC4-2133P-EE1-11 off the installed module, EE being ECC unbuffered, and this listing naming PC4-17000P-E for the same thing.
  • WD Elements Portable 5 TB, WDBU6Y0050BBK-WESN23 — 2.5" USB 3.2 Gen 1, bus-powered, no power brick — bought 2026-09-22, under #455. The drive ADR-0023 was waiting on: the off-estate copy of the household's photographs and documents, kept at another address. Not the estate's backup sets — those ride with the second age recipient (ADR-0048, copy-the-backups-offsite.md) and this drive is not that medium. 5 TB against a 2 TB source — Immich's originals on trinity's USB disk, plus Paperless's documents — so the capacity question does not come back. What it cost is not written down here, which is this entry's one gap and the thing to close when the receipt is to hand; the roadmap's rule is that a purchase is recorded when the money is spent, and the date and the part are what that rule is for. Delayed in transit. Amazon moved the delivery estimate on 2026-09-22 and refunded the delivery fee. It had still not arrived on 2026-09-26, and that day the delay went to Amazon customer service. What they answer, and the day it lands, go here. It has no vendor encryption and that is why it qualifies: ADR-0023 requires a key that is not the one only the operator holds, and a drive password is a single-holder secret behind a vendor utility, which is the failure that ADR exists to prevent moved one shelf further away. The encryption is the estate's own, over a filesystem the other person's machine can read — the pairing, and whose key it is, are #455's two open conditions, neither of which a drive satisfies. Three things the fit checks rather than assumes: it ships formatted for Windows and wants reformatting for that pairing; its cable is USB 3.0 Micro-B at the drive end, so the cable travels with the drive or the drive is a brick at the other address; and a 5 TB 2.5" drive of this class is shingled, which is fine for an archive written in one pass and not fine as a live target.
  • ViewSonic N1700W LCD, used as a rack console via the KVM
  • RJ45 Cat6 in-line couplers24
  • Cat6 patch cables25

Footnotes

  1. APC Smart-UPS ↩

  2. HPE ProLiant DL360 Gen9 ↩

  3. TP-Link 8-port gigabit switch ↩

  4. HP ProDesk 600 G4 Mini ↩

  5. MT-VIKI 8-port rackmount KVM ↩

  6. 10-outlet 1U PDU ↩

  7. Jadol 24-port patch panel ↩

  8. Intel I226 2.5 GbE card on an M.2 B+M-key adapter ↩

  9. 1U rackmount for ProDesk Mini ↩

  10. Sliding rails for ProLiant ↩

  11. 1U universal rack mount ↩

  12. HP ProDesk 600 G4 Micro, the refurbished unit that is trinity ↩

  13. Seagate Exos X20 18TB SATA 6Gb/s 7200RPM Enterprise HDD ST18000NM003D 0HR Drives ↩

  14. Seagate Exos X20 18TB 7200 SATA 6Gb/s 3.5" Enterprise Hard Drive - ST18000NM003D, eBay Refurbished ↩

  15. Samsung SM863a 960 GB, MZ-7KM960N ↩

  16. HP 2.5" SFF drive tray, 651687-001, for DL360/DL380/ML350 Gen8 and Gen9 ↩

  17. MikroTik CRS326-24G-2S+RM ↩

  18. MikroTik 24HPOW, 24 V 2.5 A ↩

  19. A1437 battery for the MacBook Pro 13" A1425 Retina ↩

  20. Dell M5Y1K 40 Wh 4-cell battery for the Inspiron 15 3000 series ↩

  21. Samsung M391A1G43EB1-CPB, 8 GB DDR4-2133 ECC UDIMM PC4-17000P-E dual rank x8 ↩

  22. WD 5TB Elements Portable External Hard Drive, WDBU6Y0050BBK-WESN ↩

  23. Cat6 in-line couplers ↩

  24. Cat6 patch cables ↩